Trosglwyddydd 10Gb/s DWDM SFP+ 80km
NODWEDDION CYNNYRCH
Yn cefnogi cyfraddau didau hyd at 11.3Gb/s
Trosglwyddydd tiwnadwy band-C llawn integredig yn fonolithig a derbynnydd APD
Bylchau sianel ITU 50 GHz gyda locer tonfedd integredig
Uchafswm hyd cyswllt o 80km
Amgaead metel, ar gyfer EMI is
2-rhyngwyneb gwifren gyda monitro Diagnostig Digidol integredig
Ôl troed SFP+ poeth-plygadwy
Manylebau sy'n cydymffurfio â SFF-8472 V10.3& SFF-8690 V1.4
Yn cydymffurfio â SFP + MSA gyda chysylltydd LC
Gwasgariad pŵer<1.65W
Amrediad tymheredd achos: -5 gradd i 70 gradd
CEISIADAU
Ethernet DWDM 10GBASE-ZR/ZW 10G
Sianel Ffibr DWDM 80KM 10G
DWDM SONET OC-192&SDH STM-64
DISGRIFIAD CYNNYRCH
Mae'r trosglwyddydd tiwnadwy HTF 10 Gb/s SFP+ yn drosglwyddydd ffibr optig integredig sy'n darparu cyswllt cyfresol cyflym ar gyfraddau signalau hyd at 11.3 Gb/s. Mae'r modiwl yn cydymffurfio â'r 10 Gigabit Enhanced Small Form Factor Pluggable (SFP+)cytundeb aml-ffynhonnell-MSA(SFF-8431) a SFF-8432,SFF-8690,SFF 8472. Mae'n cydymffurfio â'r ITU -Safon T G.698.1 gyda bylchiad sianel 50 GHz ar gyfer SONET/SDH, IEEE DWDM 10GBASE-ZR ar gyfer cyrhaeddiad 80 km (Ethernet), a DWDM 10GFC ar gyfer ceisiadau cyrhaeddiad 80 km (Fiber Channel).
Mae'r transceiver yn integreiddio'r llwybr derbynnydd a throsglwyddydd ar un modiwl. Mae'r trosglwyddydd yn cynnwys laser integredig Mach-Zehnder (MZ) tiwnadwy-band-C, sy'n galluogi trosglwyddo data dros ffibr un modd trwy gysylltydd LC o safon diwydiant. Ar ochr y derbynnydd, mae'r llif data 10 Gbps yn cael ei adennill o fwyhadur APD/traws-rwystro, a'i drosglwyddo i yrrwr allbwn. Mae'r modiwl hwn yn cynnwys rhyngwyneb trydanol poeth-plygadwy.
HTSX-DT96-80Tabl Canllaw Tonfedd
|
|
Sianel |
Tonfedd (nm) |
Amlder(THZ) |
Sianel |
Tonfedd (nm) |
Amlder(THZ) |
|
|
1 |
1568.36 |
191.15 |
51 |
1548.11 |
193.65 |
||
|
2 |
1567.95 |
191.20 |
52 |
1547.72 |
193.70 |
||
|
3 |
1567.54 |
191.25 |
53 |
1547.32 |
193.75 |
||
|
4 |
1567.13 |
191.30 |
54 |
1546.92 |
193.80 |
||
|
5 |
1566.72 |
191.35 |
55 |
1546.52 |
193.85 |
||
|
6 |
1566.31 |
191.40 |
56 |
1546.12 |
193.90 |
||
|
7 |
1565.90 |
191.45 |
57 |
1545.72 |
193.95 |
||
|
8 |
1565.50 |
191.50 |
58 |
1545.32 |
194.00 |
||
|
9 |
1565.09 |
191.55 |
59 |
1544.92 |
194.05 |
||
|
10 |
1564.68 |
191.60 |
60 |
1544.53 |
194.10 |
||
|
11 |
1564.27 |
191.65 |
61 |
1544.13 |
194.15 |
||
|
12 |
1563.86 |
191.70 |
62 |
1543.73 |
194.20 |
||
|
13 |
1563.45 |
191.75 |
63 |
1543.33 |
194.25 |
||
|
14 |
1563.05 |
191.80 |
64 |
1542.94 |
194.30 |
||
|
15 |
1562.64 |
191.85 |
65 |
1542.54 |
194.35 |
||
|
16 |
1562.23 |
191.90 |
66 |
1542.14 |
194.40 |
||
|
17 |
1561.83 |
191.95 |
67 |
1541.75 |
194.45 |
||
|
18 |
1561.42 |
192.00 |
68 |
1541.35 |
194.50 |
||
|
19 |
1561.01 |
192.05 |
69 |
1540.95 |
194.55 |
||
|
20 |
1560.61 |
192.10 |
70 |
1540.56 |
194.60 |
||
|
21 |
1560.20 |
192.15 |
71 |
1540.16 |
194.65 |
||
|
22 |
1559.79 |
192.20 |
72 |
1539.77 |
194.70 |
||
|
23 |
1559.39 |
192.25 |
73 |
1539.37 |
194.75 |
||
|
24 |
1558.98 |
192.30 |
74 |
1538.98 |
194.80 |
||
|
25 |
1558.58 |
192.35 |
75 |
1538.58 |
194.85 |
||
|
26 |
1558.17 |
192.40 |
76 |
1538.19 |
194.90 |
||
|
27 |
1557.77 |
192.45 |
77 |
1537.79 |
194.95 |
||
|
28 |
1557.36 |
192.50 |
78 |
1537.40 |
195.00 |
||
|
29 |
1556.96 |
192.55 |
79 |
1537.00 |
195.05 |
||
|
|
|||||||
|
30 |
1556.55 |
192.60 |
80 |
1536.61 |
195.10 |
|
31 |
1556.15 |
192.65 |
81 |
1536.22 |
195.15 |
|
32 |
1555.75 |
192.70 |
82 |
1535.82 |
195.20 |
|
33 |
1555.34 |
192.75 |
83 |
1535.43 |
195.25 |
|
34 |
1554.94 |
192.80 |
84 |
1535.04 |
195.30 |
|
35 |
1554.54 |
192.85 |
85 |
1534.64 |
195.35 |
|
36 |
1554.13 |
192.90 |
86 |
1534.25 |
195.40 |
|
37 |
1553.73 |
192.95 |
87 |
1533.86 |
195.45 |
|
38 |
1553.33 |
193.00 |
88 |
1533.47 |
195.50 |
|
39 |
1552.93 |
193.05 |
89 |
1533.07 |
195.55 |
|
40 |
1552.52 |
193.10 |
90 |
1532.68 |
195.60 |
|
41 |
1552.12 |
193.15 |
91 |
1532.29 |
195.65 |
|
42 |
1551.72 |
193.20 |
92 |
1531.90 |
195.70 |
|
43 |
1551.32 |
193.25 |
93 |
1531.51 |
195.75 |
|
44 |
1550.92 |
193.30 |
94 |
1531.12 |
195.80 |
|
45 |
1550.52 |
193.35 |
95 |
1530.72 |
195.85 |
|
46 |
1550.12 |
193.40 |
96 |
1530.33 |
195.90 |
|
47 |
1549.72 |
193.45 |
97 |
1529.94 |
195.95 |
|
48 |
1549.32 |
193.50 |
98 |
1529.55 |
196.00 |
|
49 |
1548.91 |
193.55 |
99 |
1529.16 |
196.05 |
|
50 |
1548.51 |
193.60 |
|
|
|
Nodyn:
Pan fydd modiwl tiwnadwy wedi'i blygio i mewn am y tro cyntaf, bydd yn mynd i sianel ddiofyn, sianel rhagosodedig HTTP-DT96-80 yw 1568.36nm, sy'n gydnaws ag ystod sianel o 1 i 99
Pan fydd y modiwl wedi'i gylchredeg pŵer, bydd yn mynd yn awtomatig i'r sianel olaf a ddewiswyd, neu pan fydd Tx yn honni ac yna'n cael ei ail-alluogi, bydd y modiwl yn dychwelyd i'r sianel olaf a ddewiswyd.
Mae mwy o gwestiynau yn ymgynghori ac mae archebion pls yn cysylltu â mi.

Tagiau poblogaidd: 10gbs dwdm sfp tunadwy+ 80km transceiver optig, Tsieina, gweithgynhyrchwyr, cyflenwyr, ffatri, addasu, prynu, pris, swmp, brand cydnaws