Nodweddion:
● Porthladd 1x10 / 100 / 1000Base-T (X) a phorthladd ffibr 1x1000Base-SX / LX / LH / ZX / SFP, Neu borthladd 1x10 / 100Base-TX a phorthladd 1x100Base-FX
● Hunan-drafod 10/100 / 1000M, modd deublyg Llawn / Hanner, auto-MDI-MDI-X
● Amddiffyniad ysgafnhau uwch, amddiffyniad IP40
● Dileu gwres rhagorol heb gefnogwr oeri
● Mewnbynnau pŵer DC deuol diangen
● -40 ℃ -85 ℃ ystod tymheredd gweithredu
Manylebau
Newid Priodweddau | |||
Maint Tabl MAC: | 8K | Maint Clustogi Pecyn: | 1Mbit |
Math o Brosesu: | Storio ac Ymlaen | Priodweddau Cyfnewid: | 148800pps (100M) |
Rhyngwynebau | |||
Rhyngwyneb Ethernet: | Rhyngwyneb Optegol Ffibr: | ||
Porthladd Ethernet: | 1-porthladd RJ45 | Porth Optegol: | 1-porthladdoedd SC / ST / FC NEU 1-porthladdoedd SC / LC |
Cyfradd Data: | Cyflymder negodi auto 10 / 100Base-T (X), modd deublyg Llawn / Hanner Cyflymder negodi awto 10/100 / 1000Base-T (X), modd deublyg Llawn / Hanner | ||
Safon: | IEEE802.3, IEEE802.3u, 10 / 100Base-T (X), IEEE802.3u, 100Base-FX NEU IEEE802.3, IEEE802.3u, IEEE802.3ab, 10/100 / 1000Base-T (X), IEEE802.3z | ||
Cysylltiad: | Cysylltiad Auto MDI-MDI-X | Tonfedd: | 1310nm / 1550nm |
Cebl UTP: | Cat5 (Pellter trosglwyddo hyd at 100M) | Ffibr Multimode: | 50 / 125um, 62.5 / 125um (Hyd trosglwyddo 2Km) |
Ffibr Modd Sengl: | 9 / 125um (Hyd at 20km, 40km, 60km, pellter trosglwyddo 80km) | ||
Pwer | |||
Foltedd Mewnbwn: | 24V DC (18-36VDC), Mewnbynnau deuol diangen | Mewnbwn Cerrynt: | <0.5a @="">0.5a> |
Gorlwytho Amddiffyniad Cyfredol: | Yn bresennol | Amddiffyn Polaredd Gwrthdroi: | Yn bresennol |
Amddiffyniad Diangen: | Yn bresennol | Cysylltiad: | 1 bloc terfynell 6-pin symudadwy |
Yr Amgylchedd Gwaith | |||
Yr Amgylchedd Gweithredol: | -40 ℃ -85 ℃ | Tymheredd Storio: | -40 ℃ -85 ℃ |
Lleithder Cymharol amgylchynol: | 5% -95% (heb gyddwyso) | ||
Safonau | |||
EMI: | FCC Rhan 15 Is-adran B Dosbarth A, EN 55022 Dosbarth A. | EMS: | EN61000-4-2 (ADC), Lefel 3 EN61000-4-3 (RS), Lefel 3 EN61000-4-4 (EFT), Lefel 3 EN61000-4-5 (Ymchwydd), Lefel 3 EN61000-4-6 (CS), Lefel 3 |
Sioc: | IEC 60068-2-27 | ||
Dirgryniad: | IEC 60068-2-6 | Diogelwch: | UL 60950-1 |
Diwydiant: | IEC61000-6-2 | Cwymp Am Ddim: | IEC 60068-2-32 |
Traffig: | NEMA TS-2 | Rheilffordd: | EN50155, EN50121-4 |
Nodweddion Corfforol | |||
Tai: | Deunydd Alloy Alwminiwm gyda Diogelu IP40 | Gosod: | Mowntio Din-Rail, mowntio waliau |
Dimensiwn: | 137mm (L) X 110mm (W) X 40mm (H) | Pwysau: | 480g |
Gwybodaeth Archebu
Rhif Rhan | Disgrifiad |
HTF-IES1110-T10105 | Porthladdoedd optegol 1x1000Base- SX / LX / LH / ZX / SFP a phorthladd 1x10 / 100 / 1000Base-T (X) RJ45, multimode 550M |
HTF-IES1110-T10120 | Porthladdoedd optegol 1x1000Base-SX / LX / LH / ZX / SFP a phorthladd 1x10 / 100 / 1000Base-T (X) RJ45, 20KM un modd |
HTF-IES1110-T10140 | Porthladdoedd optegol 1x1000Base-SX / LX / LH / ZX / SFP a phorthladd 1x10 / 100 / 1000Base-T (X) RJ45, 40KM un modd |
HTF-IES1110-T10160 | Porthladdoedd optegol 1x1000Base-SX / LX / LH / ZX / SFP a phorthladd 1x10 / 100 / 1000Base-T (X) RJ45, 60KM un modd |
HTF-IES1110-T10180 | Porthladdoedd optegol 1x1000Base-SX / LX / LH / ZX / SFP a phorthladd 1x10 / 100 / 1000Base-T (X) RJ45, modd sengl 80KM |
Rhif Rhan | Disgrifiad |
HTF-IES0110-T10102 | Porthladdoedd optegol 1x100Base- FX a phorthladd 1x10 / 100Base-T (X) RJ45, multimode 2KM |
HTF-IES0110-T10120 | Porthladdoedd optegol 1x100Base-FX a phorthladd 1x10 / 100Base-T (X) RJ45, 20KM un modd |
HTF-IES0110-T10140 | Porthladdoedd optegol 1x100Base-FX a phorthladd 1x10 / 100Base-T (X) RJ45, 40KM un modd |
HTF-IES0110-T10160 | Porthladdoedd optegol 1x100Base-FX a phorthladd 1x10 / 100Base-T (X) RJ45, modd sengl 60KM |
HTF-IES0110-T10180 | Porthladdoedd optegol 1x100Base-FX a phorthladd 1x10 / 100Base-T (X) RJ45, 80KM un modd |
Tagiau poblogaidd: Trawsnewidydd cyfryngau diwydiannol 1000m, Tsieina, gweithgynhyrchwyr, cyflenwyr, ffatri, brand wedi'i addasu, prynu, pris, swmp, cydnaws